Long-Range iNET300/iNET900 Wireless Ethernet Solution - China Factory Suppliers for Industrial Applications

Introducing the iNET300/iNET900, a cutting-edge long-range, high-speed industrial wireless IP/Ethernet solution designed for various applications. This product enables businesses to seamlessly transmit vital information over Ethernet or through a serial gateway onto IP-based networks, ensuring the secure transfer of mission-critical and revenue-generating data from fixed assets such as oil and gas wells, compressor stations, pipelines, fluid storage tanks, and utility meters. Additionally, the iNET300/iNET900 facilitates mobile network access, making it ideal for vehicle-based operations, Manufactured in China, our iNET300/iNET900 utilizes advanced 340/900MHz FHSS technology for license-free operation within the 336-344/902-928MHz ISM band. It boasts an impressive range of up to 90 miles (line-of-sight) and supports data rates of up to 512Kbps/1Mbps for over-the-air communications. This reliable solution is suitable for use in Class 1, Division 2, Groups A, B, C, and D hazardous locations, meeting industry standards for safety and performance, As a trusted supplier and factory of high-quality industrial communication solutions, we are committed to providing innovative products like the iNET300/iNET900 to enhance your operational efficiency and data management capabilities

    Long Range Wireless Ethernet

    Delivers exceptional performance with range capabilities up to 90 miles.

    High Speed Connectivity

    Supports speeds up to 512Kbps on iNET300 and up to 1Mbps on iNET900 networks.

    Robust Cyber-Security

    Protects data with multiple layers including AES-128 encryption and RADIUS authentication.

    Legacy Migration & Interfaces

    Ethernet and serial interfaces allow seamless migration of legacy serial devices to IP networks.

    Industrial Grade Performance

    UL Class 1 Div 2 certified with extended temperature range for extreme environments.

    License-Free & Plug-and-Play

    Deploy immediately with configuration that requires virtually no setup.

    VLAN Capability (802.1Q)

    Allows multiple segregated data flows over a single radio link.

    Versatile Applications

    Gateway for serial/legacy networks to IP, Video/Voice-over-IP, and mobile network access for vehicle-based operations.

    Why Use an iNET Wireless Networking Solution?
    Longest Range
    Industrial product in its class, providing the lowest cost of ownership.
    Secure Wireless Operation
    Multiple layers of protection, including a 340/900MHz physical layer, RADIUS authentication, and AES-128 data encryption with automatic key rotation.
    Reliable & Low Maintenance
    Designed and built for low failure rates and reduced maintenance costs.
    P21 Protected Access Point Option
    A chassis housing two radios in a cold standby configuration increases the availability of mission-critical point-to-multipoint networks. Remote stations can also form protected point-to-point links.
    Flexible Simultaneous Support
    Supports multiple users connecting to multiple applications via multiple protocols on the same unit or network simultaneously.
    Future Proof Open Standards
    Adheres to open standards, allowing it to interface with a wide range of external devices to bridge new and legacy technologies.
    Comprehensive Network Management
    Compatible with NETview MS™ and any standard off-the-shelf SNMP management system.
    Technical Specifications
    General
    Data Rate

    256Kbps/512Kbps (iNET300)

    512Kbps/1Mbps (iNET900)

    User configurable air link

    1,200-115.2 bps serial ports

    Frequency Band

    336-344 MHz ISM band (iNET300)

    902-928 MHz ISM band (iNET900)

    Spreading Mode
    DTS/FHSS
    Range (iNET300-256Kbps)

    Typical fixed range: 25 miles

    Maximum fixed range: 90 miles

    Typical mobile range (parked): 8 miles

    Typical mobile range (moving): 5 miles

    Range (iNET300-512Kbps)

    Typical fixed range: 15 miles

    Maximum fixed range: 25 miles

    Range (iNET900-512Kbps)

    Typical fixed range: 25 miles

    Maximum fixed range: 90 miles

    Typical mobile range (parked): 8 miles

    Typical mobile range (moving): 5 miles

    Range (iNET900-1Mbps)

    Typical fixed range: 15 miles

    Maximum fixed range: 25 miles

    Available Configurations

    Access point/remote dual gateway - serial and ethernet

    Remote Ethernet Bridge - Ethernet Only

    Remote Serial Gateway - serial only

    P21 protected station - two radios in one chassis (cold standby)

    Radio
    iNET 300

    System Gain: 150dB @ 256 Kbps | 140dB @ 512 Kbps

    Carrier Power: 0.5 to 5 / 5 to 25 watt

    Modulation: CPFSK (continuous phase FSK)

    Receiver: -101dBm @ 256 Kbps with 10-6 BER | -97dBm @ 512 Kbps with 10-6 BER

    iNET 900

    System Gain: 139dB @ 512Kbps | 134dB @ 1Mbps

    Carrier Power: 0.1 to 1 / 1 to 15 watt

    Output Impedance: 50 Ohms

    Occupied Bandwidth: 600 kHz

    Modulation: CPFSK (continuous phase FSK)

    Receiver Sensitivity: -97dBm @ 512 Kbps with 10-6 BER | -92dBm @ 1Mbps with 10-6 BER

    Physical Interfaces
    Ethernet
    10BaseT, RJ-45
    Serial

    COM1: RS-232/485/V.24, DB-9F, DCE

    COM2: RS-232/485/V.24, DB-9M, DCE

    Antenna
    TNC connector (female)
    LEDs
    Lan, Com1, Com2, power, link
    Protocols
    Wireless
    CSMA/CA (Collision Avoidance)
    Ethernet
    IEEE 802.3, Ethernet II, Spanning Tree (Bridging), IGMP
    TCP/IP
    DHCP, ICMP, UDP, TCP, ARP, Multicast, SNTP, TFTP
    Serial
    PPP, Encapsulation over IP (tunneling) for serial async multidrop protocols including Modbus, DNP.3, DF1, BSAP
    Optional
    Allen-Bradley EtherNET/IP*, Modbus/TCP
    Cyber Security Suite, Level 4
    Encryption
    AES-128 with automatic key rotation
    Authentication
    802.1x, RADIUS, EAP/TLS, PKI, PAP, CHAP
    Management
    SSL, SSH, HTTPS
    Traffic Segregation
    802.1Q VLAN
    Management
    Supported Systems & Protocols

    HTTP, HTTPS, SSH, TELNET, local console

    SNMPv1/v2/v3, MIB II, Enterprise MIB

    SYSLOG

    NETview MS™

    Environmental
    Temperature
    -40℃ to +70℃ (-40°F to +158°F)
    Humidity
    95% at 40℃ (104°F) non-condensing
    Electrical
    iNET 300 Voltage & Consumption

    Input Voltage: 10.5-16Vdc

    Current Consumption (nominal):
    Mode 13.8Vdc
    Transmit 1.2A (5W RF Output) / 5.0A (25W RF Output)
    Receive 203mA
    iNET 900 Voltage & Consumption

    Input Voltage: 10.5-30Vdc (1W), 10.5-16Vdc (15W)

    Current Consumption (nominal):
    Mode 13.8Vdc 24Vdc
    Transmit 510mA / 290mA (1W) 5.0A (15W RF Output)
    Receive 200mA 120mA
    Mechanical
    Case
    Die Cast Aluminum
    Dimensions

    iNET 300: 3.8H x 20.3W x 10.2D cm (5W) | 5.0H x 20.3W x 10.2D cm (25W)

    iNET 900: 3.15H x 17.2W x 11.2D cm (1W) | 5.0H x 20.3W x 10.2D cm (15W)

    Weight

    iNET 300: 1kg (5W), 1.2kg (25W)

    iNET 900: 908g (1W), 1.2kg (15W)

    Mounting Options
    Flat surface mount brackets, DIN rail, 19" rack tray
    P21 Option

    Case: Steel (rack mountable 2U)

    Dimensions: 8.9H x 48.3W x 35.6D cm (3.5H x 19W x 14D in)

    Weight: 7.6kg (14.7lbs) with transceivers

    Agency Approvals
    Certifications

    FCC Part 15.247

    UL/CSA Class 1 Div.21

    IC

    Frequently Asked Questions (FAQ)
    What is the maximum range supported by the iNET wireless solution?
    The iNET wireless solution supports a long range of up to 90 miles for fixed installations (specifically at 256Kbps on the iNET300 and 512Kbps on the iNET900). For mobile setups, the range is typically up to 8 miles when parked and 5 miles when moving.
    What data speeds do the iNET300 and iNET900 models offer?
    The iNET300 supports high speeds up to 512Kbps, while the iNET900 supports high speeds up to 1Mbps.
    How does the iNET system protect data transmission?
    It uses a Level 4 Cyber Security Suite that features multiple layers of protection, including AES-128 encryption with automatic key rotation, RADIUS authentication (802.1x, EAP/TLS, PKI, PAP, CHAP), SSL/SSH/HTTPS secure management, and traffic segregation using 802.1Q VLANs.
    Can I migrate legacy serial devices to modern IP networks?
    Yes. The iNET contains both Ethernet and serial interfaces (such as COM1 and COM2 supporting RS-232/485/V.24). It allows legacy serial multidrop protocols (including Modbus, DNP.3, DF1, and BSAP) to be encapsulated and tunneled over IP networks.
    What is the operating temperature range for these devices?
    The iNET is designed for extreme industrial environments and has an extended operating temperature range of -40℃ to +70℃ (-40°F to +158°F) with non-condensing humidity tolerance of up to 95%.
    What is the P21 protected Access Point option?