Leave Your Message
Products Categories
Featured Products

High-Speed iNET300/iNET900 Wireless IP/Ethernet Solution – Trusted China Suppliers & Factory for Industrial Needs

The iNET300/iNET900 is an advanced long-range, high-speed wireless IP/Ethernet solution, designed specifically for industrial applications. Ideal for businesses in China seeking reliable data transmission, this device enables seamless communication over Ethernet or through a serial gateway, connecting vital information across IP-based networks. It is particularly useful for industries collecting mission-critical and revenue-generating data from fixed assets, such as oil and gas wells, compressor stations, pipelines, fluid storage tanks, and utility meters. Additionally, it supports mobile network access for vehicle-based operations, making it an essential tool for dynamic work environments, Utilizing cutting-edge 340/900MHz FHSS technology, the iNET300/iNET900 operates in the 336-344/902-928MHz ISM band without requiring a license. It boasts an impressive range of up to 90 miles (line-of-sight) and can achieve over-the-air data rates of up to 512Kbps/1Mbps, ensuring efficient data transfer. This product is suitable for use in Class 1, Division 2, Groups A, B, C, and D hazardous locations, making it an ideal choice for factories and industrial suppliers in China. With the iNET300/iNET900, businesses can confidently enhance their operational efficiency and reliability in data communication

    Key Features
    • Long range - Up to 90 miles
    • High speed - Up to 512Kbps (iNET300) / Up to 1Mbps (iNET900)
    • Secure - multiple layers of cyber-security including:
      • AES-128 encryption
      • RADIUS authentication
    • Ethernet and serial interfaces allow migration of existing serial devices to IP networks
    • Industrial grade performance - UL Class 1 Div 2 & extended temperature range for extreme environments
    • License free - deploy immediately
    • Plug and play connectivity - configuration requires virtually no setup
    • VLAN capability (802.1Q) allows multiple segregated data flows over a single radio
    • Long range wireless Ethernet
    • Gateway for serial/legacy networks and/or devices to IP network
    • Video and/or voice-over-IP
    • Mobile network access for vehicle-based operation
    Why Use An iNET Solution?
    • Longest range - industrial product in its class. Providing lowest cost of ownership.
    • Secure - wireless operation with multiple layers of protection, including a 340/900MHz physical layer, RADIUS authentication and AES-128 data encryption with automatic key rotation.
    • Reliable - Designed and built for low failure rates and reduced maintenance costs.
    • Reliable Protection - The P21 protected Access Point (a chassis housing two radios in a cold standby configuration) increases the availability of mission-critical point-to-multipoint networks. P21 Remote stations can also be used to form protected point-to-point links.
    • Flexible - The iNET supports multiple users connecting to multiple applications via multiple protocols on the same iNET unit or the same network - simultaneously!
    • Future proof - The iNET adheres to open standards, allowing it to interface with a wide range of external devices enabling both new and old technologies to communicate.
    • Comprehensive Network Management - Compatible with NETview MS™ and any standard off-the-shelf SNMP management system.
    Technical Specifications
    Specification Details
    General
    Data Rate 256Kbps/512Kbps (iNET300)
    512Kbps/1Mbps (iNET900)
    User configurable air link
    1,200-115.2 bps serial ports
    Frequency Band 336-344 MHz ISM band (iNET300)
    902-928 MHz ISM band (iNET900)
    Spreading Mode DTS/FHSS
    Range (iNET300-256Kbps) Typical fixed range: 25 miles
    Maximum fixed range: 90 miles
    Typical mobile range (parked): 8 miles
    Typical mobile range (moving): 5 miles
    Range (iNET300-512Kbps) Typical fixed range: 15 miles
    Maximum fixed range: 25 miles
    Range (iNET900-512Kbps) Typical fixed range: 25 miles
    Maximum fixed range: 90 miles
    Typical mobile range (parked): 8 miles
    Typical mobile range (moving): 5 miles
    Range (iNET900-1Mbps) Typical fixed range: 15 miles
    Maximum fixed range: 25 miles
    Available Configurations Access point/remote dual gateway - serial and ethernet
    Remote Ethernet Bridge - Ethernet Only
    Remote Serial Gateway - serial only
    P21 protected station - two radios in one chassis (cold standby)
    Radio
    iNET 300
    System Gain 150dB @ 256 Kbps
    140dB @ 512 Kbps
    Carrier Power 0.5 to 5 / 5 to 25 watt
    Modulation CPFSK (continuous phase FSK)
    Receiver -101dBm @ 256 Kbps with 10-6 BER
    -97dBm @ 512 Kbps with 10-6 BER
    iNET 900
    System Gain 139dB @ 512Kbps
    134dB @ 1Mbps
    Carrier Power 0.1 to 1 / 1 to 15 watt
    Output Impedance 50 Ohms
    Occupied Bandwidth 600 kHz
    Modulation CPFSK (continuous phase FSK)
    Receiver Sensitivity -97dBm @ 512 Kbps with 10-6 BER
    -92dBm @ 1Mbps with 10-6 BER
    Physical Interfaces
    Ethernet 10BaseT, RJ-45
    Serial COM1: RS-232/485/V.24, DB-9F, DCE
    COM2: RS-232/485/V.24, DB-9M, DCE
    Antenna TNC connector (female)
    LEDs Lan, Com1, Com2, power, link
    Protocols
    Wireless CSMA/CA (Collision Avoidance)
    Ethernet IEEE 802.3, Ethernet II, Spanning Tree (Bridging), IGMP
    TCP/IP DHCP, ICMP, UDP, TCP, ARP, Multicast, SNTP, TFTP
    Serial PPP, Encapsulation over IP (tunneling) for serial async multidrop protocols including Modbus, DNP.3, DF1, BSAP
    Optional Allen-Bradley EtherNET/IP*, Modbus/TCP
    Cyber Security Suite, Level 4
    Encryption AES-128 with automatic key rotation
    Authentication 802.1x, RADIUS, EAP/TLS, PKI, PAP, CHAP
    Management SSL, SSH, HTTPS
    Traffic Segregation 802.1Q VLAN
    Management
    Supported Protocols HTTP, HTTPS, SSH, TELNET, local console
    SNMPv1/v2/v3, MIB II, Enterprise MIB
    SYSLOG
    NETview MS™
    Environmental
    Temperature -40℃ to +70℃ (-40°F to +158°F)
    Humidity 95% at 40℃ (104°F) non-condensing
    Electrical
    iNET 300
    Input Voltage 10.5-16Vdc
    Current Consumption Transmit: 1.2A (5W RF Output) / 5.0A (25W RF Output) @ 13.8Vdc
    Receive: 203mA @ 13.8Vdc
    iNET 900
    Input Voltage 10.5-30Vdc (1W), 10.5-16Vdc (15W)
    Current Consumption Transmit: 510mA (13.8Vdc) / 290mA (24Vdc) for 1W Output; 5.0A (13.8Vdc) for 15W RF Output
    Receive: 200mA @ 13.8Vdc / 120mA @ 24Vdc
    Mechanical
    Case Material Die Cast Aluminum
    Dimensions iNET 300: 3.8H x 20.3W x 10.2D cm (5W) / 5.0H x 20.3W x 10.2D cm (25W)
    iNET 900: 3.15H x 17.2W x 11.2D cm (1W) / 5.0H x 20.3W x 10.2D cm (15W)
    Weight iNET 300: 1kg (5W) / 1.2kg (25W)
    iNET 900: 908g (1W) / 1.2kg (15W)
    Mounting Options Flat surface mount brackets, DIN rail, 19" rack tray
    P21 Option
    Case & Design Steel (rack mountable 2U)
    Dimensions 8.9H x 48.3W x 35.6D cm (3.5H x 19W x 14D in)
    Weight 7.6kg (14.7lbs) with transceivers
    Agency Approvals
    Standards FCC Part 15.247
    UL/CSA Class 1 Div. 21
    IC
    Frequently Asked Questions (FAQ)
    What is the maximum communication range of the iNET system?

    The iNET system offers a long-range wireless capability of up to 90 miles for fixed installations, depending on configurations and operational frequencies.

    What are the main differences between the iNET300 and iNET900 models?

    The iNET300 operates on the 336-344 MHz ISM band with data rates up to 512Kbps, while the iNET900 operates on the 902-928 MHz ISM band and supports higher speeds up to 1Mbps.

    What security features are integrated into the iNET wireless solution?

    It features a Level 4 Cyber Security Suite, including AES-128 encryption with automatic key rotation, RADIUS authentication, 802.1x, EAP/TLS, and 802.1Q VLAN support for traffic segregation.

    Can the iNET system operate in extreme industrial environments?

    Yes, it is designed for industrial-grade performance, featuring an extended operating temperature range of -40°C to +70°C (-40°F to +158°F) and UL/CSA Class 1 Division 2 certification.

    What is the P21 protected Access Point configuration?

    The P21 option is a protected station housing two radios in a cold standby configuration within a single steel 2U chassis, ensuring high availability for mission-critical networks.

    Does the iNET wireless system require a dedicated operator license?

    No, the iNET solutions operate on license-free ISM bands (336-344 MHz for iNET300 and 902-928 MHz for iNET900), allowing rapid deployment without licensing delays.