China Suppliers Super LoRa Series: Industry-Leading Point-to-Multipoint SCADA Communications for Factory Monitoring

Introducing our premier licensed point-to-multipoint SCADA communications solution, designed specifically for industrial monitoring and control across critical sectors such as electricity, water, oil, and gas. As a leading supplier in China, our factory utilizes smart and secure technologies to ensure industry-leading speed and reliability. Optimize your operations with our cutting-edge systems that empower seamless communication and enhance productivity in industrial environments. Choose us for unparalleled solutions tailored to meet the demands of modern industries

    Key Features of Super-LoRa
    High capacity
    To meet the growing number of data-intensive applications in the SCADA environment, the Super-LoRa provides data rates of up to 216 kbit/s in 50 kHz licensed channels.
    Secure
    With its defense in depth approach, including AES encryption, authentication, address filtering and user access control including RADIUS, the Super-LoRa protects against vulnerabilities and malicious attacks.
    Future-proof
    The Super-LoRa supports multiple serial and Ethernet interfaces in a single, compact form factor, and is standards-based for long term incorporation into SCADA networks while protecting the legacy investment in serial devices.
    Advanced L2 / L3 capabilities
    Selectable L2 Bridge or L3 Router modes, with VLAN, advanced QoS, filtering and IP header and payload compression attributes to support narrow bandwidth channels and mission critical traffic while meeting increasing security and IP network policy requirements. Advanced payload and Ethernet / IP / TCP / UDP header compression.
    Adaptable
    The Super-LoRa integrates into a range of network topologies, with each unit configurable as a master station, repeater or remote station; connect multiple RTUs / PLCs to a single radio.
    Flexible interfaces
    The data interfaces can be configured for serial or Ethernet operation; a range of options are supported, including two serial and two Ethernet, one serial and three Ethernet, or four Ethernet ports. Support for NMEA GPS receiver option.
    Link efficiency
    Adaptive Coding and Modulation (ACM) and forward error correction maintains the integrity of the wireless connection while an effective channel access scheme and IP routing ensures efficient transfer of data across the Super-LoRa network.
    Reliable and robust
    The Aprisa SR+ requires no manual component tuning and maintains its high-power output and performance over a wide temperature range.
    Easily managed
    An easy-to-use GUI supports local element management via HTTPS and remote element management over the air and SNMP support allows network-wide monitoring and control via a variety of supported third party network management systems.
    The Super-LoRa in Brief
    Frequency bands of 135 – 175, 215 – 240, 400 – 520, 757 – 758 and 787 – 788, 896 – 902 and 928 – 960 MHz
    RS-232 and IEEE 802.3 protocols with multiple port options
    Software selectable 12.5 kHz, 15 kHz, 25 kHz 30 kHz and 50 kHz channel sizes. For other channel sizes please consult WDS
    Full and half duplex operation
    Single or dual frequency
    Gross data rates greater than 200 kbit/s
    256, 192 or 128bit AES encryption
    Adaptive Coding and Modulation: QPSK to 64 QAM
    Advanced forward error correction
    Ethernet and IP / TCP / UDP header compression (ROHC) and payload compression
    Software selectable dual / single antenna port operation
    Transparent to all common SCADA protocols
    Dedicated alarm port
    Protected master station and remote station options
    Power optimized option
    Radio GPS coordinates
    –40 to +70 °C operational temperature
    210 mm (W) x 130 mm (D) x 41.5 mm (H)
    FCC and IC standards compliant
    Seamlessly integrates with Aprisa XE point-to-point radio
    Super-LoRa Applications
    Electricity grid: distribution automation control and protection in MV / HV distribution / transmission
    Smart grid: concentrator communications and GPRS replacement
    Oil & Gas: production metering, lift pump automation
    AMI / AMR: high density data concentrator backhauls
    Renewables: wind farm, tidal, hydro automation
    Water and wastewater: flow, level, pressure modulation automation and pump status
    Technical Specifications
    GENERAL
    NETWORK TOPOLOGY Point-to-multipoint (PMP), Master, Remote, Repeater
    NETWORK INTEGRATION Serial and Ethernet (router or bridge mode)
    PROTOCOLS
    ETHERNET IEEE802.3, 802.1d/q/p
    SERIAL Legacy RS-232 transport
    WIRELESS Proprietary
    SCADA Transparent to all common SCADA protocols such as Modbus, IEC 60870-5-101/104, DNP3 or similar
    RADIO FREQ BAND TUNING RANGE TUNE STEP
    FREQUENCY RANGE
    (Notes 4 & 5)
    150 MHz 135 – 175 MHz 0.625 kHz
    230 MHz 215 – 240 MHz 0.625 kHz
    400 MHz 400 – 470 MHz 6.25 kHz
    450 MHz 450 – 520 MHz 6.25 kHz
    700 MHz 757 – 758 & 787 – 788 MHz 6.25 kHz
    896 MHz 896 – 902 MHz 6.25 kHz
    928 MHz 928 – 960 MHz 6.25 kHz
    CHANNEL SIZE 12.5kHz, 15kHz, 25kHz, 30kHz and 50kHz software selectable
    DUPLEX Single frequency half-duplex, Dual frequency half-duplex, Dual frequency full-duplex
    FREQUENCY STABILITY ± 0.5 ppm
    FREQUENCY AGING < 1 ppm / annum
    TRANSMITTER
    MAX PEAK ENVELOPE POWER (PEP) 10.0 W (+40 dBm)
    AVERAGE POWER OUTPUT
    (Note 2)
    64 QAM 0.01–2.5W (+10 to +34dBm, in 1dB steps)
    16 QAM 0.01–3.2W (+10 to +35dBm, in 1dB steps)
    QPSK 0.01–5.0W (+10 to +37dBm, in 1dB steps)
    4-CPFSK 0.01–10.0W (+10 to +40dBm, in 1dB steps)
    ADJACENT CHANNEL POWER < –60 dBc
    TRANSIENT ADJACENT CHANNEL POWER < –60 dBc
    SPURIOUS EMISSIONS < –37 dBm
    ATTACK TIME < 1.5 ms
    RELEASE TIME < 0.5 ms
    DATA TURNAROUND TIME < 2 ms
    EMISSION DESIGNATOR SUFFIX QPSK G1D, QAM D1D
    RECEIVER MODULATION 12.5 kHz 25 kHz 50 kHz
    SENSITIVITY (BER < 10-6)
    max coded
    64 QAM –103 dBm –99 dBm –96 dBm
    16 QAM –110 dBm –107 dBm –104 dBm
    QPSK –115 dBm –112 dBm –109 dBm
    4-CPFSK –113 dBm –110 dBm –107 dBm
    ADJACENT CHANNEL SELECTIVITY
    (Note 1)
    Absolute > –47 dBm > –37 dBm > –37 dBm
    Relative [> 48 dB] [> 58 dB] [> 58 dB]
    CO-CHANNEL REJECTION (QPSK) > –10 dB
    CO-CHANNEL REJECTION (64 QAM) > –20 dB
    INTERMODULATION RESPONSE REJECTION > –35 dBm [> 60 dB Note 1]
    BLOCKING OR DESENSITISATION > –17 dBm [> 78 dB Note 1]
    SPURIOUS RESPONSE REJECTION > –32 dBm [> 63 dB Note 1]
    MODEM 12.5 kHz (Note 3) 15 kHz 25 kHz 30 kHz 50 kHz
    BAND 220, 400, 450 700, 896, 928 135 220 220, 400, 450, 700, 896, 928 135 135, 220, 400, 700, 896, 928
    64 QAM 54 kbit/s 60 kbit/s 54 kbit/s 60 kbit/s 96 kbit/s / 120 kbit/s 96 kbit/s 216 kbit/s 240 kbit/s
    16 QAM 36 kbit/s 40 kbit/s 36 kbit/s 40 kbit/s 64 kbit/s / 80 kbit/s 64 kbit/s 144 kbit/s 160 kbit/s
    QPSK 18 kbit/s 20 kbit/s 18 kbit/s 20 kbit/s 32 kbit/s / 40 kbit/s 32 kbit/s 72 kbit/s 80 kbit/s
    4-CPFSK 9.6 kbit/s 9.6 kbit/s 9.6 kbit/s 9.6 kbit/s 19.2 kbit/s 19.2 kbit/s 38.4 kbit/s 38.4 kbit/s
    OCC BW 10.7 kHz 12.0 kHz 10.7 kHz 12.0 kHz 19.8 kHz / 24.5 kHz 19.8 kHz 43.0 kHz 48.0 kHz
    FORWARD ERROR CORRECTION Variable Reed Solomon plus convolutional code
    ADAPTIVE BURST SUPPORT Adaptive Coding and Modulation
    SECURITY
    DATA ENCRYPTION 256, 192 or 128 bit AES
    DATA AUTHENTICATION CCM
    INTERFACES
    ETHERNET 2, 3 or 4 port RJ45 10/100Base-T switch (specified at order)
    SERIAL 2, 1 or 0 port RJ45 RS-232 (specified at order). Additional RS-232/RS-485 port via USB converter (optional)
    MANAGEMENT 1 x USB micro type B (device port), 1 x USB standard type A (host port), 1 x Alarm port RJ45
    ANTENNA 2 x TNC 50-ohm female. Software selectable single or dual port operation
    LEDs Status: OK, MODE, AUX, TX, RX. Diagnostics: RSSI, traffic port status
    TEST BUTTON Toggles LEDs between diagnostics / status
    PRODUCT OPTIONS
    DATA PORT CONFIGURATION 2 x Ethernet ports + 2 serial ports, 3 x Ethernet ports + 1 serial port, 4 x Ethernet ports
    POWER OPTIMIZED Providing optimized power and sleep mode
    PROTECTED STATION Providing hot-swappable/hot-standby redundant hardware switching (13.8VDC or 48VDC)
    GPS RECEIVER Support for NMEA GPS receiver with radio coordinates
    POWER
    INPUT VOLTAGE 10 – 30VDC (13.8V nominal)
    RECEIVE (All bands) < 3W (217mA at 13.8VDC) active, < 2W (145mA at 13.8VDC) idle, < 0.5W (36mA at 13.8VDC) sleep
    TRANSMIT (135 and 220 MHz) < 26W (1884mA at 13.8VDC)
    TRANSMIT (400, 450, 700, 896, 928 MHz) < 28W (2028mA at 13.8VDC)
    MECHANICAL & ENVIRONMENTAL
    DIMENSIONS 210 mm (W) x 130 mm (D) x 41.5 mm (H) / 8.27” (W) x 5.12” (D) x 1.63” (H)
    WEIGHT 1.25 kg (2.81 lbs)
    MOUNTING Wall, Rack or DIN rail
    OPERATING TEMPERATURE –40 to +70 ˚C (–40 to +158 ˚F)
    HUMIDITY Maximum 95 % non-condensing
    MANAGEMENT & DIAGNOSTICS
    LOCAL ELEMENT Web server with full control / diagnostics, Partial diagnostics via LEDs/test button, Software upgrade from PC/USB
    REMOTE ELEMENT Over-the-air remote element management with control / diagnostics, Network software upgrade over-the-air
    NETWORK SNMPv2 and SNMPv3 security support for integration with external network management systems
    COMPLIANCE FCC CFR47 Part 24 / 27 / 90 / 101, IC RSS 119 / RSS 134
    BAND 135 FCC ID: UIPSQ135M150 IC: 6772A-SQ135M150
    BAND 220 FCC ID: UIPSQ215M141 IC: 6772A-SQ215M141
    BAND 400 FCC ID: UIPSQ400M1311 IC: 6772A-SQ400M1311
    BAND 450 FCC ID: UIPSQ450M140 IC: N/A
    BAND 700 FCC ID: UIPSQ757M160 IC: N/A
    BAND 896 FCC ID: UIPSQ896M141 IC: 6772A-SQ896M141
    BAND 928 FCC ID: UIPSQ928M141 IC: 6772A-SQ928M141
    EMC FCC CFR47 Part 15, EN 301 489-5, ICES-003
    SAFETY EN 60950, Class 1 division 2 for hazardous locations
    ENVIRONMENTAL ETS 300 019 Class 3.4, IEEE 1613 Class 2, IEC 61850-3, Ingress Protection IP51
    Notes:
    The receiver figures are shown in typical fixed jamming dBm values and dB values [in brackets] relative to the sensitivity. Relative values are given for QPSK modulation and max coded FEC. Refer to the Aprisa SR+ User Manual for a complete list of modulation and coding levels.
    Please consult 4RF for availability.
    The gross data rate for the 12.5 kHz channel size varies with regulatory compliance.
    The 450 MHz and 700 MHz bands are only available for FCC.
    The receive tuning range is specified. The transmit tuning range is 896 - 960 MHz.
    Graphics
    Frequently Asked Questions (FAQ)
    What is the maximum data capacity of the Super-LoRa?
    The Super-LoRa provides high-capacity data rates of up to 216 kbit/s in 50 kHz licensed channels to meet the requirements of data-intensive SCADA applications.
    Which frequency bands does the Super-LoRa operate on?
    It supports frequency bands of 135 – 175 MHz, 215 – 240 MHz, 400 – 520 MHz, 757 – 758 MHz, 787 – 788 MHz, 896 – 902 MHz, and 928 – 960 MHz.
    How does the Super-LoRa secure SCADA networks?
    It utilizes a defense-in-depth security approach, featuring 256, 192, or 128-bit AES encryption, CCM data authentication, address filtering, and user access control including RADIUS.
    What interfaces and port configurations are supported?
    The Super-LoRa supports flexible Ethernet and serial configurations, including options for 2 Ethernet + 2 serial ports, 3 Ethernet + 1 serial port, or 4 Ethernet ports, along with USB management and alarm ports.
    What are the primary applications of the Super-LoRa?
    Key applications include distribution automation in electricity and smart grids, production metering in oil & gas, AMI/AMR data concentrator backhauls, wind/hydro automation, and water/wastewater pump status monitoring.
    What is the environmental tolerance of the device?
    The Super-LoRa is built robustly to operate in a wide temperature range of –40 to +70 °C and up to 95% non-condensing humidity, compliant with IP51 ingress protection standards.