Leave Your Message
Products Categories
Featured Products

China Suppliers Super LoRa Series: Industrial SCADA Communication Network & Serial Radio Factory Solutions

Introducing our advanced point-to-multipoint SCADA communication solution, designed specifically for industrial monitoring and control in the electricity, water, oil, and gas sectors. As a leading supplier in China, our factory ensures the highest standards of security and industry-leading speed, making us the preferred choice for businesses seeking reliable and efficient communication systems. Experience unparalleled performance with our technology, tailored to meet the needs of industrial enterprises worldwide

    High capacity

    To meet the growing number of data-intensive applications in the SCADA environment, the Super-LoRa provides data rates of up to 216 kbit/s in 50 kHz licensed channels.

    Secure

    With its defense in depth approach, including AES encryption, authentication, address filtering and user access control including RADIUS, the Super-LoRa protects against vulnerabilities and malicious attacks.

    Future-proof

    The Super-LoRa supports multiple serial and Ethernet interfaces in a single, compact form factor, and is standards-based for long term incorporation into SCADA networks while protecting the legacy investment in serial devices.

    Advanced L2 / L3 capabilities

    Selectable L2 Bridge or L3 Router modes, with VLAN, advanced QoS, filtering and IP header and payload compression attributes to support narrow bandwidth channels and mission critical traffic while meeting increasing security and IP network policy requirements. Advanced payload and Ethernet / IP / TCP / UDP header compression.

    Adaptable

    The Super-LoRa integrates into a range of network topologies, with each unit configurable as a master station, repeater or remote station; connect multiple RTUs / PLCs to a single radio.

    Flexible interfaces

    The data interfaces can be configured for serial or Ethernet operation; a range of options are supported, including two serial and two Ethernet, one serial and three Ethernet, or four Ethernet ports. Support for NMEA GPS receiver option.

    Link efficiency

    Adaptive Coding and Modulation (ACM) and forward error correction maintains the integrity of the wireless connection while an effective channel access scheme and IP routing ensures efficient transfer of data across the Super-LoRa network.

    Reliable and robust

    The Aprisa SR+ requires no manual component tuning and maintains its high-power output and performance over a wide temperature range.

    Easily managed

    An easy-to-use GUI supports local element management via HTTPS and remote element management over the air and SNMP support allows network-wide monitoring and control via a variety of supported third party network management systems.

    The Super-LoRa in brief
    • Frequency bands of 135 – 175, 215 – 240, 400 – 520, 757 – 758 and 787 – 788, 896 – 902 and 928 – 960 MHz
    • RS-232 and IEEE 802.3 protocols with multiple port options
    • Software selectable 12.5 kHz, 15 kHz, 25 kHz 30 kHz and 50 kHz channel sizes. For other channel sizes please consult WDS
    • Full and half duplex operation
    • Single or dual frequency
    • Gross data rates greater than 200 kbit/s
    • 256, 192 or 128bit AES encryption
    • Adaptive Coding and Modulation: QPSK to 64 QAM
    • Advanced forward error correction
    • Ethernet and IP / TCP / UDP header compression (ROHC) and payload compression
    • Software selectable dual / single antenna port operation
    • Transparent to all common SCADA protocols
    • Dedicated alarm port
    • Protected master station and remote station options
    • Power optimized option
    • Radio GPS coordinates
    • –40 to +70 °C operational temperature
    • 210 mm (W) x 130 mm (D) x 41.5 mm (H)
    • FCC and IC standards compliant
    • Seamlessly integrates with Aprisa XE point-to-point radio
    Super-LoRa applications
    • Electricity grid: distribution automation control and protection in MV / HV distribution / transmission
    • Smart grid: concentrator communications and GPRS replacement
    • Oil & Gas: production metering, lift pump automation
    • AMI / AMR: high density data concentrator backhauls
    • Renewables: wind farm, tidal, hydro automation
    • Water and wastewater: flow, level, pressure modulation automation and pump status
    Technical Specifications
    GENERAL
    NETWORK TOPOLOGY Point-to-multipoint (PMP), Master, Remote, Repeater
    NETWORK INTEGRATION Serial and Ethernet (router or bridge mode)
    PROTOCOLS
    ETHERNET IEEE802.3, 802.1d/q/p
    SERIAL Legacy RS-232 transport
    WIRELESS Proprietary
    SCADA Transparent to all common SCADA protocols such as Modbus, IEC 60870-5-101/104, DNP3 or similar
    RADIO FREQ BAND TUNING RANGE TUNE STEP
    FREQUENCY RANGE
    (Note 4, Note 5)
    150 MHz 135 – 175 MHz 0.625 kHz
    230 MHz 215 – 240 MHz 0.625 kHz
    400 MHz 400 – 470 MHz 6.25 kHz
    450 MHz 450 – 520 MHz 6.25 kHz
    700 MHz 757 – 758 & 787 – 788 MHz 6.25 kHz
    896 MHz 896 – 902 MHz 6.25 kHz
    928 MHz 928 – 960 MHz 6.25 kHz
    CHANNEL SIZE 12.5kHz, 15kHz, 25kHz, 30kHz and 50kHz software selectable
    DUPLEX Single frequency half-duplex, Dual frequency half-duplex, Dual frequency full-duplex
    FREQUENCY STABILITY ± 0.5 ppm
    FREQUENCY AGING < 1 ppm / annum
    TRANSMITTER
    MAX PEAK ENVELOPE POWER (PEP) 10.0 W (+40 dBm)
    AVERAGE POWER OUTPUT
    (Note 2)
    64 QAM 0.01–2.5W (+10 to +34dBm, in 1dB steps)
    16 QAM 0.01–3.2W (+10 to +35dBm, in 1dB steps)
    QPSK 0.01–5.0W (+10 to +37dBm, in 1dB steps)
    4-CPFSK 0.01–10.0W (+10 to +40dBm, in 1dB steps)
    ADJACENT CHANNEL POWER < –60 dBc
    TRANSIENT ADJACENT CHANNEL POWER < –60 dBc
    SPURIOUS EMISSIONS < –37 dBm
    ATTACK TIME < 1.5 ms
    RELEASE TIME < 0.5 ms
    DATA TURNAROUND TIME < 2 ms
    EMISSION DESIGNATOR SUFFIX QPSK G1D, QAM D1D
    RECEIVER 12.5 kHz 25 kHz 50 kHz
    SENSITIVITY (BER < 10-6)
    max coded
    64 QAM –103 dBm –99 dBm –96 dBm
    16 QAM –110 dBm –107 dBm –104 dBm
    QPSK –115 dBm –112 dBm –109 dBm
    4-CPFSK –113 dBm –110 dBm –107 dBm
    ADJACENT CHANNEL SELECTIVITY
    (Note 1)
    > –47 dBm > –37 dBm > –37 dBm
    [> 48 dB] [> 58 dB] [> 58 dB]
    CO-CHANNEL REJECTION
    max coded QPSK
    > –10 dB
    CO-CHANNEL REJECTION
    max coded 64 QAM
    > –20 dB
    INTERMODULATION RESPONSE REJECTION > –35 dBm [> 60 dB Note 1]
    BLOCKING OR DESENSITISATION > –17 dBm [> 78 dB Note 1]
    SPURIOUS RESPONSE REJECTION > –32 dBm [> 63 dB Note 1]
    MODEM 12.5 kHz
    (Note 3)
    15 kHz 25 kHz 30 kHz 50 kHz
    BAND 220, 400, 450 700, 896, 928 135 220 220, 400, 450, 700, 896, 928 135 135, 220, 400, 700, 896, 928
    64 QAM 54 kbit/s 60 kbit/s 54 kbit/s 60 kbit/s 96 kbit/s (at 220/400/450/700) / 120 kbit/s (at 896/928) 96 kbit/s 216 kbit/s 240 kbit/s
    16 QAM 36 kbit/s 40 kbit/s 36 kbit/s 40 kbit/s 64 kbit/s / 80 kbit/s 64 kbit/s 144 kbit/s 160 kbit/s
    QPSK 18 kbit/s 20 kbit/s 18 kbit/s 20 kbit/s 32 kbit/s / 40 kbit/s 32 kbit/s 72 kbit/s 80 kbit/s
    4-CPFSK 9.6 kbit/s 9.6 kbit/s 9.6 kbit/s 9.6 kbit/s 19.2 kbit/s 19.2 kbit/s 38.4 kbit/s 38.4 kbit/s
    OCC BW 10.7 kHz 12.0 kHz 10.7 kHz 12.0 kHz 19.8 kHz / 24.5 kHz 19.8 kHz 43.0 kHz 48.0 kHz
    FORWARD ERROR CORRECTION Variable Reed Solomon plus convolutional code
    ADAPTIVE BURST SUPPORT Adaptive Coding and Modulation
    SECURITY
    DATA ENCRYPTION 256, 192 or 128 bit AES
    DATA AUTHENTICATION CCM
    INTERFACES
    ETHERNET 2, 3 or 4 port RJ45 10/100Base-T switch (specified at order)
    SERIAL 2, 1 or 0 port RJ45 RS-232 (specified at order). Additional RS-232/RS-485 port via USB converter (optional)
    MANAGEMENT 1 x USB micro type B (device port), 1 x USB standard type A (host port), 1 x Alarm port RJ45
    ANTENNA 2 x TNC 50-ohm female. Software selectable single or dual port operation
    LEDs Status: OK, MODE, AUX, TX, RX. Diagnostics: RSSI, traffic port status
    TEST BUTTON Toggles LEDs between diagnostics /status
    PRODUCT OPTIONS
    DATA PORT CONFIGURATION 2 x Ethernet ports + 2 serial ports, 3 x Ethernet ports + 1 serial port, 4 x Ethernet ports
    POWER OPTIMIZED Providing optimized power and sleep mode
    PROTECTED STATION Providing hot-swappable/hot-standby redundant hardware switching (13.8VDC or 48VDC)
    GPS RECEIVER Support for NMEA GPS receiver with radio coordinates
    POWER
    INPUT VOLTAGE 10 – 30VDC (13.8V nominal)
    RECEIVE All bands < 3W (217mA at 13.8VDC) in active receive state, < 2W (145mA at 13.8VDC) in idle receive state, < 0.5W (36mA at 13.8VDC) in sleep mode
    TRANSMIT 35 and 220 MHz: < 26W (1884mA at 13.8VDC)
    400, 450, 700, 896, 928 MHz: < 28W (2028mA at 13.8VDC)
    MECHANICAL
    DIMENSIONS 210 mm (W) x 130 mm (D) x 41.5 mm (H) / 8.27’ (W) x 5.12’ (D) x 1.63’ (H)
    WEIGHT 1.25 kg (2.81 lbs)
    MOUNTING Wall, Rack or DIN rail
    ENVIRONMENTAL
    OPERATING TEMPERATURE –40 to +70 ˚C (–40 to +158 ˚F)
    HUMIDITY Maximum 95 % non-condensing
    MANAGEMENT & DIAGNOSTICS
    LOCAL ELEMENT Web server with full control / diagnostics, Partial diagnostics via LEDs and test button, Software upgrade from PC or USB flash drive
    REMOTE ELEMENT Over-the-air remote element management with control / diagnostics, Network software upgrade over-the-air
    NETWORK SNMPv2 and SNMPv3 security support for integration with external network management systems
    COMPLIANCE
    RF FCC CFR47 Part 24 / 27 / 90 / 101, IC RSS 119 / RSS 134
    BAND FCC ID: IC:
    135 UIPSQ135M150 6772A-SQ135M150
    220 UIPSQ215M141 6772A-SQ215M141
    400 UIPSQ400M1311 6772A-SQ400M1311
    450 UIPSQ450M140 N/A
    700 UIPSQ757M160 N/A
    896 UIPSQ896M141 6772A-SQ896M141
    928 UIPSQ928M141 6772A-SQ928M141
    EMC FCC CFR47 Part 15, EN 301 489-5, ICES-003
    SAFETY EN 60950, Class 1 division 2 for hazardous locations
    ENVIRONMENTAL ETS 300 019 Class 3.4, IEEE 1613 Class 2, IEC 61850-3, Ingress Protection IP51
    Notes:
    1. The receiver figures are shown in typical fixed jamming dBm values and dB values [in brackets] relative to the sensitivity. Relative values are given for QPSK modulation and max coded FEC. Refer to the Aprisa SR+ User Manual for a complete list of modulation and coding levels.
    2. Please consult 4RF for availability.
    3. The gross data rate for the 12.5 kHz channel size varies with regulatory compliance.
    4. The 450 MHz and 700 MHz bands are only available for FCC.
    5. The receive tuning range is specified. The transmit tuning range is 896 - 960 MHz.
    Graphics
    Frequently Asked Questions
    What is the maximum data rate supported by Super-LoRa?
    Super-LoRa provides gross data rates of up to 216 kbit/s in 50 kHz licensed channels (and up to 240 kbit/s depending on the frequency band) to meet data-intensive application demands in SCADA environments.
    What security features are integrated into the Super-LoRa system?
    Super-LoRa features a defense-in-depth security approach, incorporating 128, 192, or 256-bit AES encryption, CCM data authentication, address filtering, and user access control including RADIUS to safeguard against malicious attacks.
    Which frequency bands does the Super-LoRa operate on?
    The system supports multiple frequency bands, including 135 – 175 MHz, 215 – 240 MHz, 400 – 520 MHz, 757 – 758 MHz, 787 – 788 MHz, 896 – 902 MHz, and 928 – 960 MHz.
    What are the primary applications of Super-LoRa?
    Super-LoRa is designed for critical infrastructure networks, including electricity distribution automation, smart grid concentrator communications, oil & gas production metering, high-density AMI/AMR backhauls, renewable energy automation (wind/solar/hydro), and water/wastewater systems.
    What interface configurations are available?
    Super-LoRa supports flexible data port configurations, including options for 2 Ethernet ports + 2 serial ports, 3 Ethernet ports + 1 serial port, or 4 Ethernet ports, allowing seamless integration of both legacy serial and modern IP devices.
    What is the operating temperature range and environmental compliance of Super-LoRa?
    The device features an operational temperature range of –40 to +70 °C, supports up to 95% non-condensing humidity, and complies with environmental standards including ETS 300 019 Class 3.4, IEEE 1613 Class 2, and IEC 61850-3 with IP51 ingress protection.