Leave Your Message
Products Categories
Featured Products

China Suppliers Super LoRa Series: Advanced Network & Serial Radio for Industrial SCADA Communications Factory

Experience cutting-edge SCADA communications with our industry-leading point-to-multipoint solutions, designed for smart and secure industrial monitoring and control in the electricity, water, oil, and gas sectors. As a trusted supplier in China, our factory delivers unmatched speed and reliability, ensuring seamless operations and enhanced efficiency for your business needs. Choose our advanced technology to elevate your industrial applications and stay ahead in the competitive landscape

    High capacity

    To meet the growing number of data-intensive applications in the SCADA environment, the Super-LoRa provides data rates of up to 216 kbit/s in 50 kHz licensed channels.

    Secure

    With its defense in depth approach, including AES encryption, authentication, address filtering and user access control including RADIUS, the Super-LoRa protects against vulnerabilities and malicious attacks.

    Future-proof

    The Super-LoRa supports multiple serial and Ethernet interfaces in a single, compact form factor, and is standards-based for long term incorporation into SCADA networks while protecting the legacy investment in serial devices.

    Advanced L2 / L3 capabilities

    Selectable L2 Bridge or L3 Router modes, with VLAN, advanced QoS, filtering and IP header and payload compression attributes to support narrow bandwidth channels and mission critical traffic.

    Adaptable

    The Super-LoRa integrates into a range of network topologies, with each unit configurable as a master station, repeater or remote station; connect multiple RTUs / PLCs to a single radio.

    Flexible interfaces

    The data interfaces can be configured for serial or Ethernet operation; options include two serial and two Ethernet, one serial and three Ethernet, or four Ethernet ports. Supports NMEA GPS receiver.

    Link efficiency

    Adaptive Coding and Modulation (ACM) and forward error correction maintains link integrity, while an effective channel access scheme and IP routing ensures efficient transfer of data.

    Reliable and robust

    The Aprisa SR+ requires no manual component tuning and maintains its high-power output and performance over a wide temperature range.

    Easily managed

    An easy-to-use GUI supports local element management via HTTPS and remote element management over the air. SNMP support allows network-wide monitoring and control.

    The Super-LoRa in brief
    Frequency bands of 135 – 175, 215 – 240, 400 – 520, 757 – 758 and 787 – 788, 896 – 902 and 928 – 960 MHz
    RS-232 and IEEE 802.3 protocols with multiple port options
    Software selectable 12.5 kHz, 15 kHz, 25 kHz 30 kHz and 50 kHz channel sizes
    Full and half duplex operation, single or dual frequency
    Gross data rates greater than 200 kbit/s
    256, 192 or 128bit AES encryption
    Adaptive Coding and Modulation: QPSK to 64 QAM with advanced forward error correction
    Ethernet and IP / TCP / UDP header compression (ROHC) and payload compression
    Transparent to all common SCADA protocols with dedicated alarm port
    Protected master station and remote station options
    –40 to +70 °C operational temperature; 210 mm (W) x 130 mm (D) x 41.5 mm (H)
    FCC and IC standards compliant; integrates with Aprisa XE point-to-point radio
    Super-LoRa applications
    Electricity grid: distribution automation control and protection in MV / HV distribution / transmission
    Smart grid: concentrator communications and GPRS replacement
    Oil & Gas: production metering, lift pump automation
    AMI / AMR: high density data concentrator backhauls
    Renewables: wind farm, tidal, hydro automation
    Water and wastewater: flow, level, pressure modulation automation and pump status
    Technical Specifications
    GENERAL  
    NETWORK TOPOLOGY Point-to-multipoint (PMP), Master, Remote, Repeater
    NETWORK INTEGRATION Serial and Ethernet (router or bridge mode)
    PROTOCOLS  
    ETHERNET IEEE802.3, 802.1d/q/p
    SERIAL Legacy RS-232 transport
    WIRELESS Proprietary
    SCADA Transparent to all common SCADA protocols such as Modbus, IEC 60870-5-101/104, DNP3 or similar
    RADIO FREQ BAND TUNING RANGE TUNE STEP
    FREQUENCY RANGE 150 MHz 135 – 175 MHz 0.625 kHz
      230 MHz 215 – 240 MHz 0.625 kHz
      400 MHz 400 – 470 MHz 6.25 kHz
    (Note 4) 450 MHz 450 – 520 MHz 6.25 kHz
    (Note 4) 700 MHz 757 – 758 & 787 – 788 MHz 6.25 kHz
    (Note 5) 896 MHz 896 – 902 MHz 6.25 kHz
    (Note 5) 928 MHz 928 – 960 MHz 6.25 kHz
    CHANNEL SIZE 12.5kHz, 15kHz, 25kHz, 30kHz and 50kHz software selectable
    DUPLEX Single frequency half-duplex, Dual frequency half-duplex, Dual frequency full-duplex
    FREQUENCY STABILITY ± 0.5 ppm
    FREQUENCY AGING < 1 ppm / annum
    TRANSMITTER  
    MAX PEAK ENVELOPE POWER (PEP) 10.0 W (+40 dBm)
    AVERAGE POWER OUTPUT 64 QAM 0.01–2.5W (+10 to +34dBm, in 1dB steps)
      16 QAM 0.01–3.2W (+10 to +35dBm, in 1dB steps)
      QPSK 0.01–5.0W (+10 to +37dBm, in 1dB steps)
    (Note 2) 4-CPFSK 0.01–10.0W (+10 to +40dBm, in 1dB steps)
    ADJACENT CHANNEL POWER < –60 dBc
    TRANSIENT ADJACENT CHANNEL POWER < –60 dBc
    SPURIOUS EMISSIONS < –37 dBm
    ATTACK TIME < 1.5 ms
    RELEASE TIME < 0.5 ms
    DATA TURNAROUND TIME < 2 ms
    EMISSION DESIGNATOR SUFFIX QPSK G1D, QAM D1D
    RECEIVER   12.5 kHz 25 kHz 50 kHz
    SENSITIVITY (BER < 10-6) max coded 64 QAM –103 dBm –99 dBm –96 dBm
    max coded 16 QAM –110 dBm –107 dBm –104 dBm
    max coded QPSK –115 dBm –112 dBm –109 dBm
    max coded 4-CPFSK –113 dBm –110 dBm –107 dBm
    ADJACENT CHANNEL SELECTIVITY   > –47 dBm > –37 dBm > –37 dBm
    (Note 1)   [> 48 dB] [> 58 dB] [> 58 dB]
    CO-CHANNEL REJECTION max coded QPSK > –10 dB
    CO-CHANNEL REJECTION max coded 64 QAM > –20 dB
    INTERMODULATION RESPONSE REJECTION > –35 dBm [> 60 dB Note 1]
    BLOCKING OR DESENSITISATION > –17 dBm [> 78 dB Note 1]
    SPURIOUS RESPONSE REJECTION > –32 dBm [> 63 dB Note 1]
    MODEM 12.5 kHz (Note 3) 15 kHz 25 kHz 30 kHz 50 kHz
    BAND 220, 400, 450 700, 896, 928 135 220 220, 400, 450, 700, 896, 928 135 135, 220, 400, 700, 896, 928
    64 QAM 54 kbit/s 60 kbit/s 54 kbit/s 60 kbit/s 96 kbit/s 120 kbit/s 96 kbit/s 216 kbit/s 240 kbit/s
    16 QAM 36 kbit/s 40 kbit/s 36 kbit/s 40 kbit/s 64 kbit/s 80 kbit/s 64 kbit/s 144 kbit/s 160 kbit/s
    QPSK 18 kbit/s 20 kbit/s 18 kbit/s 20 kbit/s 32 kbit/s 40 kbit/s 32 kbit/s 72 kbit/s 80 kbit/s
    4-CPFSK 9.6 kbit/s 9.6 kbit/s 9.6 kbit/s 9.6 kbit/s 19.2 kbit/s 19.2 kbit/s 19.2 kbit/s 38.4 kbit/s 38.4 kbit/s
    OCC BW 10.7 kHz 12.0 kHz 10.7 kHz 12.0 kHz 19.8 kHz 24.5 kHz 19.8 kHz 43.0 kHz 48.0 kHz
    FORWARD ERROR CORRECTION Variable Reed Solomon plus convolutional code
    ADAPTIVE BURST SUPPORT Adaptive Coding and Modulation
    SECURITY  
    DATA ENCRYPTION 256, 192 or 128 bit AES
    DATA AUTHENTICATION CCM
    INTERFACES  
    ETHERNET 2, 3 or 4 port RJ45 10/100Base-T switch (specified at order)
    SERIAL 2, 1 or 0 port RJ45 RS-232 (specified at order). Additional RS-232/RS-485 port via USB converter (optional)
    MANAGEMENT 1 x USB micro type B (device port), 1 x USB standard type A (host port), 1 x Alarm port RJ45
    ANTENNA 2 x TNC 50-ohm female. Software selectable single or dual port operation
    LEDs Status: OK, MODE, AUX, TX, RX. Diagnostics: RSSI, traffic port status
    TEST BUTTON Toggles LEDs between diagnostics /status
    PRODUCT OPTIONS  
    DATA PORT CONFIGURATION 2 x Ethernet ports + 2 serial ports, 3 x Ethernet ports + 1 serial port, 4 x Ethernet ports
    POWER OPTIMIZED Providing optimized power and sleep mode
    PROTECTED STATION Providing hot-swappable/hot-standby redundant hardware switching (13.8VDC or 48VDC)
    GPS RECEIVER Support for NMEA GPS receiver with radio coordinates
    POWER  
    INPUT VOLTAGE 10 – 30VDC (13.8V nominal)
    RECEIVE All bands < 3W (217mA at 13.8VDC) in active receive state, < 2W (145mA at 13.8VDC) in idle receive state, < 0.5W (36mA at 13.8VDC) in sleep mode
    TRANSMIT 35 and 220 MHz < 26W (1884mA at 13.8VDC)
    400, 450, 700, 896, 928 MHz < 28W (2028mA at 13.8VDC)
    MECHANICAL  
    DIMENSIONS 210 mm (W) x 130 mm (D) x 41.5 mm (H) / 8.27’ (W) x 5.12’ (D) x 1.63’ (H)
    WEIGHT 1.25 kg (2.81 lbs)
    MOUNTING Wall, Rack or DIN rail
    ENVIRONMENTAL  
    OPERATING TEMPERATURE –40 to +70 ˚C (–40 to +158 ˚F)
    HUMIDITY Maximum 95 % non-condensing
    MANAGEMENT & DIAGNOSTICS
    LOCAL ELEMENT Web server with full control / diagnostics, Partial diagnostics via LEDs and test button, Software upgrade from PC or USB flash drive
    REMOTE ELEMENT Over-the-air remote element management with control / diagnostics, Network software upgrade over-the-air
    NETWORK SNMPv2 and SNMPv3 security support for integration with external network management systems
    COMPLIANCE  
    RF FCC CFR47 Part 24 / 27 / 90 / 101, IC RSS 119 / RSS 134
      BAND FCC ID: IC:
      135 UIPSQ135M150 6772A-SQ135M150
      220 UIPSQ215M141 6772A-SQ215M141
      400 UIPSQ400M1311 6772A-SQ400M1311
      450 UIPSQ450M140 N/A
      700 UIPSQ757M160 N/A
      896 UIPSQ896M141 6772A-SQ896M141
      928 UIPSQ928M141 6772A-SQ928M141
    EMC FCC CFR47 Part 15, EN 301 489-5, ICES-003
    SAFETY EN 60950, Class 1 division 2 for hazardous locations
    ENVIRONMENTAL ETS 300 019 Class 3.4, IEEE 1613 Class 2, IEC 61850-3, Ingress Protection IP51
    Notes:
    1. The receiver figures are shown in typical fixed jamming dBm values and dB values [in brackets] relative to the sensitivity. Relative values are given for QPSK modulation and max coded FEC. Refer to the Aprisa SR+ User Manual for a complete list of modulation and coding levels.
    2. Please consult 4RF for availability.
    3. The gross data rate for the 12.5 kHz channel size varies with regulatory compliance.
    4. The 450 MHz and 700 MHz bands are only available for FCC.
    5. The receive tuning range is specified. The transmit tuning range is 896 - 960 MHz.
    Graphics
    Frequently Asked Questions
    What is the maximum data rate of the Super-LoRa?
    The Super-LoRa provides high capacity to meet data-intensive applications in SCADA environments, offering gross data rates of up to 216 kbit/s in 50 kHz licensed channels (and up to 240 kbit/s depending on the specific frequency band).
    What frequency bands does the Super-LoRa support?
    The Super-LoRa supports a wide range of frequency bands including 135 – 175 MHz, 215 – 240 MHz, 400 – 520 MHz, 757 – 758 MHz, 787 – 788 MHz, 896 – 902 MHz, and 928 – 960 MHz.
    What security features protect the Super-LoRa network?
    It features a defense-in-depth security approach including 256, 192, or 128-bit AES data encryption, CCM authentication, address filtering, and user access control options like RADIUS to protect against malicious attacks.
    What are the primary applications of Super-LoRa?
    Super-LoRa is designed for critical infrastructure including electricity grid distribution automation, smart grid concentrator communications, oil & gas production metering, AMI/AMR high-density backhauls, renewable energy automation (wind, tidal, hydro), and water/wastewater management.
    How flexible are the physical data interfaces?
    The data interfaces are software configurable for serial or Ethernet operation. Port configuration options include two serial and two Ethernet, one serial and three Ethernet, or four Ethernet ports. It also supports an optional NMEA GPS receiver.
    What environmental standards does the device comply with?
    The Super-LoRa operates reliably in temperatures ranging from –40 to +70 °C, complies with ETS 300 019 Class 3.4, IEEE 1613 Class 2, and IEC 61850-3 standards, and features an IP51 ingress protection rating.